Operating Conditions (T = 25°C)
Table 1. DC Characteristics
Values
Parameter
Symbol
Min
Typ
Max
Unit
Note
Output Amplifier Drain Supply
VDD
14
15
16
V
Reset DC Bias
VDR
12
13
14.5
V
(1)
Output Gate DC Bias
VGS
5.5
6
6.5
V
Photosensitive Zone and
Register DC Bias
VT
6
6.5
7
V
(2)
Substrate Bias
VSS
0.0
0.0
Test Point 1
TP1
VDD
Test Points 2 and 3
TP2, TP3
VSS
Notes:
1. It is recommended to maintain VDR at VDD - 2V.
2. VT nominal =
(---V----Φ-----T---)--h----i-g---h-----+-----(---V----Φ----T---)---l--o---w-- ± 5%
2
3. No use for operation – For testing purpose only.
V
(3)
V
(3)
Basic Internal
Configuration
SΦECHA and ΦRA
SΦECHB and ΦRB
internal to TH7841A
Table 2. Selection of Nominal Mode
Option
Implementation
Note
VINH (16) Connected to VSS
Internal Sampling
SΦECHA (4) and ΦECHA (3) Strapped
(1)
SΦECHB (24) and ΦECHB (25) Strapped
Internal Reset
ΦRA (5) and ΦRB (21) Connected to VDD
Note: 1. Make the straps as short as possible to avoid any parasitic coupling to these connec-
tions. The load capacitance introduced by the strap should not exceed 5 pF.