English
Language : 

AT22V10 Datasheet, PDF (3/11 Pages) ATMEL Corporation – High Speed UV Erasable Programmable Logic Device
AT22V10/L
D.C. Characteristics
Symbol Parameter
Condition
Min Typ Max Units
ILI
Input
Load
Current
VIN
V
=
-0.1
V
to
VCC+1
10
µA
ILO
Output Leakage
Current
VOUT = -0.1 V to VCC+0.1 V
10
µA
ICC
Power Supply
Current
VCC = MAX,
VIN = GND,
Outputs Open
AT22V10-15,-20 Com.
Ind., Mil.
AT22V10-25,-35(2)
AT22V10L(2)
Com.
Ind., Mil.
90
mA
100 mA
55
mA
1.7
12
mA
2.0
15
mA
ICC2
Clocked Power VCC = MAX,
Supply Current Outputs Open
AT22V10L(2)
Com.
Ind., Mil.
2.0
mA/MHz
2.0
mA/MHz
IOS (1)
Output Short
Circuit Current
VOUT = 0.5 V
-120 mA
VIL
Input Low Voltage
-0.6
0.8
V
VIH
Input High Voltage
2.0
VCC+0.75 V
VOL
Output Low
Voltage
VIN = VIH or VIL,
VCC = MIN
IOL = 16 mA
IOL = 12 mA
IOL = 24 mA
Com.,Ind.
Mil.
Com.
0.5
V
0.5
V
0.8
V
VOH
Output High
Voltage
VIN=VIH or VIL,
VCC=MIN
IOH = -100 µA
IOH = -4.0 mA
VCC-0.3
2.4
V
V
Notes: 1. Not more than one output at a time should be shorted. Du-
ration of short circuit test should not exceed 30 sec.
2. See ICC vs. Frequency curves in the back of this data sheet.
A.C. Characteristics, Commercial and Industrial
Symbol Parameter
tPD
Input or Feedback to
Non-Registered Output
tEA Input to Output Enable
tER Input to Output Disable
tCF Clock to Feedback
tCO Clock to Output
tS
Input or Feedback Setup Time
tH Hold Time
tP
Clock Period
tW Clock Width
External Feedback 1/(tS+tCO)
FMAX Internal Feedback 1/(tS + tCF)
No Feedback 1/(tP)
tAW Asynchronous Reset Width
Asynchronous Reset,
tAR Synchronous Preset,
Recovery Time
tAP
Asynchronous Reset to
Registered Output Reset
AT22V10-15
Min Typ Max
10 15
10 15
10 15
0
1 2.5
0
7 10
10
8
0
12
6
50.0
80.0
83.3
15
8
AT22V10/L-20
Min Typ Max
12 20
20
20
0
4
8
0
8 12
12
8
0
20
10
41.6
50.0
50.0
20
9
AT22V10/L-25
Min Typ Max Units
15 25 ns
15 25 ns
15 25 ns
0
5 10 ns
0 10 15 ns
15 12
ns
0
ns
24
ns
12
ns
33.3 MHz
40.0 MHz
41.6 MHz
25 10
ns
15
8
20 12
25 15
ns
12 20
15 22
18 25 ns
1-99