AT16244
AC Characteristics
AT16244F
Applicable over recommended operating range from Ta = 0°C to +70°C, VCC = 5.0V +/- 5% (unless otherwise noted)
Symbol
Parameter
Test Conditions Min Typ Max
Units
tPHL
Propagation Delay
CL = 50 pF
tPLH
2.5
ns
tPZH
Output Enable Time
CL = 50 pF
tPZL
5.5
ns
tPHZ
Output Disable Time
CL = 50 pF
tPLZ
6.0
ns
tSK(1)
Output Skew
CL = 50 pF
0.5
ns
∆tPHL(1)
∆tPLH
Propagation Delay vs Output Loading
1.3 1.5
ns/100 pF
Note: 1. This parameter is guaranteed but not 100% tested.
AT16244G
Applicable over recommended operating range from Ta = 0°C to +70°C, VCC = 5.0V +/- 5% (unless otherwise noted)
Symbol
Parameter
Test Conditions Min Typ Max
Units
tPHL
Propagation Delay
tPLH
tPZH
Output Enable Time
tPZL
tPHZ
Output Disable Time
tPLZ
tSK(1)
Output Skew
∆tPHL(1)
∆tPLH
Propagation Delay vs Output Loading
Note: 1. This parameter is guaranteed but not 100% tested.
Test Circuits(1,2)
CL = 50 pF
CL = 50 pF
CL = 50 pF
CL = 50 pF
2.0
5.5
5.0
0.5
0.9 1.1
Switch Position
ns
ns
ns
ns
ns/100 pF
VCC
7.0V
Pulse
Generator
500Ω
VIN
VOUT
D.U.T.
50 pF
RT
500Ω
CL
Test
Switch
Open Drain
Disable Low
Enable Low
Closed
All Other Tests
Open
Definitions:
CL= Load capacitance; Includes jig and probe capacitance.
RT=Termination resistance; Should be equal to ZOUT of the
Pulse Generator.
Note:
1. Pulse Generator: Rate ≤ 1.0 MHz, tF ≤ 2.5 ns, tR ≤ 2.5 ns.
2. AC tests are done with a single bit switching, and
timings need to be derated when multiple outputs are
switching in the same direction simultaneously. This derating
should not exceed 0.5 ns for 16 inputs switching
simultaneously.
5-5