10. Electrical Characteristics (Continued)
-VS = 13.0 V, Tamb = 25° C, reference point pin 2, unless otherwise specified
Parameters
Test Conditions
Pins
Symbol
Min.
Typ.
Pulse Blocking, Tacho Monitoring
Logic-on
Logic-off
Input current
Output resistance
Frequency-to-voltage Converter
V18 = VTOFF = 1.25 V
V18 = V16
18
-VTON
3.7
1.5
18
-VTOFF
1.25
18
II
0.3
14.5
18
RO
1.5
6
Input bias current
Input voltage limitation
II = -1 mA
II = +1 mA
(see Figure 10-7 on
page 17)
8
IIB
0.6
-VI
660
8
+VI
7.25
Turn-on threshold
Turn-off threshold
Charge Amplifier
8
-VTON
100
8
-VTOFF
20
50
Discharge current
C5 = 1 nF, (see Figure
10-17 on page 21)
9
Idis
0.5
Charge transfer voltage
Charge transfer gain
Conversion factor
9 to 16
Vch
I10/I9
9, 10
Gi
C5 = 1 nF, R6 = 100 kΩ
(see Figure 10-17 on
K
page 21)
6.50
6.70
7.5
8.3
5.5
Output operating range
Linearity
10 to 16
VO
0-6
±1
Soft Start, f/V Converter Non-active (see Figure 10-2 on page 15 and Figure 10-4 on page 16)
Starting current
V13 = V16, V8 = V2
13
IO
20
45
Final current
V13 = 0.5
13
IO
50
85
f/V Converter Active (see Figure 10-3 on page 15, Figure 10-5 on page 16 and Figure 10-6 on page 16)
Starting current
Final current
Discharge current
V13 = V16
13
V13 = 0.5
Restart pulse
13
Automatic Retriggering (see Figure 10-13 on page 19, Pin 5)
IO
2
4
IO
30
55
IO
0.5
3
Repetition rate
R5-3 = 0
tpp
3
4.5
R5-3 = 15 kΩ
tpp
20
Load Limiting (see Figure 10-9 on page 17, Figure 10-10 on page 18 and Figure 10-11 on page 18)
Operating voltage range
Offset current
Input current
Output current
Overload ON
V10 = V16
V14 = V2 via 1 kΩ
V10 = 4.5 V
V14 = 300 mV
14
14
15-16
14
15-16
15-16
VI
IO
IO
II
IO
VTON
-1.0
5
0.1
60
90
110
7.05
7.4
Max.
Unit
V
1.0
V
1
µA
µA
10
kΩ
2
µA
750
mV
8.05
V
150
mV
mV
mA
6.90
V
9.0
mV/Hz
V
%
55
µA
130
µA
7
µA
80
µA
10
mA
6
tp
tp
+1.0
V
12
µA
1.0
µA
120
µA
140
µA
7.7
V