English
Language : 

AT24C256SC_14 Datasheet, PDF (10/13 Pages) ATMEL Corporation – Schmitt Trigger, Filtered Inputs for Noise Suppression
Figure 12. Random Read
address and serially clocks out the data word. The microcontroller does not respond
with a zero but does generate a following stop condition (refer to Figure 12).
P0
Notes: 1. * = DON’T CARE bit
2. † = DON’T CARE bit for the 128K
SEQUENTIAL READ: Sequential reads are initiated by either a current address read or
a random address read. After the microcontroller receives a data word, it responds with
an acknowledge. As long as the EEPROM receives an acknowledge, it will continue to
increment the data word address and serially clock out sequential data words. When the
memory address limit is reached, the data word address will “roll over” and the sequen-
tial read will continue. The sequential read operation is terminated when the
microcontroller does not respond with a zero but does generate a following stop condi-
tion (refer to Figure 13).
Figure 13. Sequential Read
10 AT24C128SC/AT24C256SC
1661B–SEEPR–04/04