English
Language : 

ALQ07 Datasheet, PDF (6/28 Pages) Astec America, Inc – Technical Reference Notes
6
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage
to the device. These are absolute stress ratings only. Functional operation of the
device is not implied at these or any other conditions in excess of those given in the
operational sections of the IPS. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Device Symbol Min
Typ.
Max
Unit
Continuous:
Input Voltage
All
VI
0
Transient (100ms)
All
VI, trans
0
-
80
Vdc
-
100
Vdc
Operating Ambient Temperature
All
Ta
-40
-
60
ºC
Storage Temperature
All
TSTG
-55
-
125
ºC
Operating Humidity
Basic Input-Output Isolation
(Conditions: 50µA for 5 sec,
slew rate of 1500V/10sec)
All
-
All
-
-
-
95
%
-
-
1,500
Vdc
Output Power
All
Po,max
-
-
30
W
ALQ07 DC-DC Converter Technical Reference Notes
DATE: Aug., 9, 2003