English
Language : 

LPQ110 Datasheet, PDF (2/2 Pages) Astec America, Inc – 110 Watts
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
LPQ112
5V
2A
12 V
0A
-12 V
0A
±5-25 V
0A
9A
4.5 A
0.7 A
2.5 A
11 A
5A
1.0 A
3A
15 A
±2%
9A
±3%
1.5 A
±5%
3.5 A
±3%
LPQ113
5V
2A
15 V
0A
-15 V
0A
±5-25 V
0A
9A
4.5 A
0.7 A
2.5 A
11 A
5A
1.0 A
3A
15 A
±2%
9A
±3%
1.5 A
±5%
3.5 A
±3%
LPQ114
5V
12 V
-12 V
24 V
2A
0A
0A
0.5 A
9A
4.5 A
0.7 A
3.5 A
11 A
5A
1.0 A
4.5 A
15 A
9A
1.5 A
5A
±2%
±3%
±5%
+10 / -5%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th O/P adjustable 5 to 25 V, factory set at 5 V.
5. Minimum loads are required.
Note: -B suffix added to model number indicates L bracket option.
-B Bracket
Ripple
P/P (PARD)3
50 mV
120 mV
120 mV
240 mV, max.
50 mV
150 mV
150 mV
240 mV, max.
50 mV
120 mV
120 mV
240 mV
Pin Assignments
Connector LPQ112 LPQ113 LPQ114
SK1-1
SK1-3
SK1-5
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
SK2-10
SK2-11
SK2-12
SK201-1
SK201-2
SK202-1
SK202-2
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
+5 V
+5 V
+5 V
Common
Common
Common
Common
+15 V
+15 V
-15 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+24 V
Common
+sense
-sense
POK
GND
Mating Connectors
AC Input: Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC Outputs: Molex 09-50-8121 (USA)
09-91-1200 (UK)
PINS: 08-58-0111
Remote sense/Power fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Astec Connector Kit #70-841-008, includes all of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± 0.02”
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Warranty: 1 year
8. Weight: 1.25 lb./0.57 kg
www.astecpower.com
4.28"
(108.6)
2.5"
(63.5)
2.2"
(56)
0.86"
(21.8)
0.25"
(6.35)
4.0"
(101.6)
3.5"
(88.9)
1
3
0.25"
(6.35)
1.80"
(45.7)
0.12"
(3)
#6-32 PEM
6 places
6.4"
(162.6)
7.3"
(185.5)
5.9"
(150.0)
4th O/P ADJ
6.5"
(165.1)
7.0"
(177.8)
M2
SK 202
(POK)
1
2
3
SK 201 1 2
(+S) 1
(-S) 2
4
5
6
7
8
9
10
11
12
GND
N
L
SK 1
M1
0.156" (4)
DIA (4 places)
103