English
Language : 

LPQ110 Datasheet, PDF (1/2 Pages) Astec America, Inc – 110 Watts
110 Watts
LPQ110 Series
Total Power: 80-110 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Quad
Special Features
• Universal input
• High efficiency
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5 V output
• Overvoltage protection
• Overload protection
• Adjustable floating 4th output
(On LPQ112 and LPQ113)
• Power fail
• Optional L bracket (-B suffix)
• Cover kit available LPX110-C
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50°
to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground
leakage current
85-264 VAC
120-300 VDC
47-440 Hz
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
2.5 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
80 W for convection;
110 W with 30 CFM forced air
±5% min. on main; 5-25 V on 4th
output on LPQ112 and LPQ113
±2% on output 1; ±3% on outputs
2, 3 & 4
20 ms @ 80 W load, 115 VAC
nominal line
Short circuit protection on all
outputs. Case overload protected @
110-145% above peak rating
5.7-6.7 VDC on main output.
Latching type, recycle AC to reset.
Logic Control
Power Failure
Remote sense
TTL logic signal goes high 50-150
msec after 5 V output. It goes low at
least 4 msec before loss of regulation.
Compensates for 0.5 V lead drop
min. Will operate without remote
sense connected. Reverse
connection protected.
Electrical Specs
VDE
UL
CSA
NEMKO
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1245 (LC #84997)
E132002
LR53982C
P94102464
1423, 1424, 1425
rev 12.10.03
Technical Support: (888) 41-ASTEC or (407) 241-2752
102
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662