SA40-1313 Datasheet, PDF (1/2 Pages) Astec America, Inc – 40 Watts
40 Watts
SA40-1313 Series
Total Power: 40 Watts
Input Voltage: 85-264 VAC
# of Outputs: Triple
Special Features
• Low cost
• Universal input
• 3” x 5” footprint
• Built-in EMI filter
• Low output ripple
• 100% computerized final testing
• Overvoltage protection
• Overload protection
Environmental
Operating temperature: 0° to 50°C ambient
Storage temperature: -40° to 85°C
Thermal regulation: ±.04% per °C
MTBF: >100,000 hours at full load and 25°C
ambient conditions per MIL-HDBK-217E
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
Power factor
EMI filter
Output
Maximum power
Cross regulation
Overshoot
Hold-up time
Overvoltage protection
Safety ground
Leakage current
Overload protection
85-264 VAC
47-63 Hz
<25 A peak @ 115 VAC;
<50 A peak @ 230 VAC,
cold start at 25°C
1 A max. (RMS) @ 115 VAC;
0.5 A max (RMS) @ 230 VAC
70% typical at full load, nominal line
>0.65
Meets FCC 20780 Class B and
VDE 0871 Level B
40 W convection
±2% on output 1;
±5% on outputs 2, 3
None
20 ms @ full load, 115 VAC nominal
line
+5 V trip voltage less than 6.8 V;
recycle AC safety ground to reset
< 0.5 mA @ 250 VAC, 50 Hz
Short circuit protected on all outputs
Safety
TUV IEC950
UL
UL1950
CSA CSA22.2-234
VDE VDE0805, IEC 950
EN
60950
CB
certificate and report
R9153228
E132002
LR53982C
11774-3336-1164
UL330-132002 / USA
88
America’s (USA): 1-888-41-ASTEC