LPS350 Datasheet, PDF (1/2 Pages) Astec America, Inc – 350 Watts
350 Watts
LPS350 Series
Total Power: 350 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Electrical Specs
Special Features
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• Supervisory output 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Cover -C
• 130 KHz switching frequency
• Optional with fan cover -CF
• Optional end-mounted fan - CEF
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
Output
Maximum power
Adjustment range
Supervisory outputs
mA x2
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote on/off
DC-OK
Remote sense
85-264 VAC; 120-300 VDC
47-440 Hz
38 A max., cold start @ 25°C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and
radiated
VDE 0878 PT3 Class B conducted and
radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
With cover: 350 W with 30 CFM forced
air,
(-C) (-CF) (-CEF)
2:1 wide ratio
5 V @ 500 mA regulated, 12 V @ 150
20 ms @ 350 W load, 115 VAC nominal
line
at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7-6.7 VDC. Other models
10% to 25% above nominal output
TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after
the output. It goes low when there is
loss of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection protected.
Safety
VDE
UL UL1950
CSA
NEMKO
BABT
CB
CE
0805/EN60950 (IEC950)
E186249
CSA 22.2-234 Level 5
EN 60950/EMKO-TUE
(74-sec) 203
EN60950/BS7002
Certificate and report
Mark (LVD)
21310-3336-0001
LR109492C
P98102115
608857, 608858, 609097
5734, 6280, 6281
rev 07.11.05
128
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662