English
Language : 

HPS35 Datasheet, PDF (1/5 Pages) Astec America, Inc – 350-1400 Watts
350-1400 Watts
HPS35 Series
Total power: 350W
Input voltage: 90-264VAC
# of outputs: One & standby
Special Features
• Active Power Factor Correction
• EN61000-3-2 compliant
• CISPR22, EN55022 Class-B conducted/radiated EMI
• EN61000 immunity standards
• 5VSB@2A
• Overvoltage protection (OVP)
• Overcurrent protection (OCP)
• Overtemperature protection (OTP)
• AC OK signal and indicator LED
• DC OK signal and indicator LED
• Remote inhibit
• Remote Sense on main output
• Hot Plug
• N+1 Redundant
• Optional I2C board (pending)
Voltage Monitoring
Current Monitoring
Remote on/off
DC OK / AC OK
Temperature
Fan fail
Environmental
Operating temperature: 0°C to +50°C ambient, derate
output @ 2.5% per degree from 50°C to 70°C
Shock: Operating - 4g, half since, 22 ms minimum
duration, all 6 faces
Non-operating: 30g, half since, 6 ms minimum
duration, all 6 faces
Random Vibration
Operating: 1g rms, 20 min/axis
Non-operating: 12.5g rms, 20min/axis
Humidity: 95% non-condensing
Storage temperature: -40°C to +85°C
Temperature coefficient: 0.04% per °C
Cooling: Internal DC fans
Electrical Specs
Input
Input voltage
Frequency
Inrush current
Efficiency
Power factor
Turn-on time
EMI filter standard
Leakage current standard
Radiated EMI
Holdup time
AC OK
Harmonic distortion
Isolation
90-264 VAC typical
47-440 Hz
40 A peak typical @ 25°C
80% typ @ full load, 230 VAC
0.98 typical @ 115 VAC, full load
AC - ON 2 sec.
Inhibit / Enable 160 ms
CISPR 22 EN55022 Level “B”
<0.5 mA max @ 230 VAC @ 60Hz
(per module)
CISPR 22 EN55022 Level “B”
20 ms minimum
(independent of input VAC)
5 ms early warning minimum before
outputs lose regulation
Meets EN61000-3-2
Meets EN60950
Output
Adjustability
±5% of nominal output voltage
Overall reg
<3%
Ripple
1% of Vout Pk - Pk
(20 MHz bandwidth)
Dynamic response
4% with 50% load step
Recovery time
To within 1% in <300 µsec
Overcurrent protection 115%-130% of rated output current
Short circuit protection
Protected for continuous short circuit.
Auto recovery.
Overvoltage protection 120 - 140% . AC Reset.
Reverse voltage protection 100% of rated output current
Thermal protection
Main and Aux disabled when internal
temp exceeds safe operating range.
Remote sense
Up to 0.5 V total drop
Single wire parallel
Current share to within 10% of total
rated current on main output
DC OK
±5% of nominal
Minimum load*
None required (as a standalone module)
Standby voltage
5 VDC @2A max. present whenever AC
input is applied
Global Inhibit
Logic “0”
*3A minimum required for current share operation
Safety
UL
UL60950-1, 1st Ed. (April 1, 2003)
CSA CSA C22.2 60950-1-03
TUV EN60950-1:2001 (1st Ed.)
CB
IEC60950-1, 1st Ed. (2001)
CE
Mark (LVD)
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-96622
rev 02.24.05