English
Language : 

PRAS1 Datasheet, PDF (45/52 Pages) ASM GmbH – Angle Sensors and Encoders Contents
PRODIS ®
PD-INC
Digital process meter for incremental sensors
Programmable
parameters /  
value range
Wiring basic unit
RS-232 interface
Value range display, offset, limit values
Divisor, Multiplier
Other programmable parameters
Signal T
-999999 to +999999
0 to 999999
Counting direction, decimal point position, last-value
memory, Z signal evaluation, display brightness
Manual zero, key lock, display value hold, Z release,
relative measurement activation
Signals
Sensor +UB
Sensor 0 V (GND)
Signal A
Signal A
Signal B
Signal B
Signal Z (zero signal)
Signal Z (zero signal)
Signal T (reference signal)
Signal T (reference signal)
GND
PD-INC-24VDC
Excitation +24 V
Excitation 0 V (GND)
PD-INC-230VAC
Excitation
Protective ground
Connector X1  
pin no.
1
2
4
5
6
7
8
9
10
11
12
Connector X2  
pin no.
13
14
13, 15
14
Rear view without
comparator outputs
Level
Data format
Transmission rate
Signals
TxD
RxD
GND
5 ........ 1
RS-232
1.....................................12 13 14 15
X1
X2
13 14 15
X1
X2
PD-INC-24VDC
PD-INC-230VAC
RS-232: ±8 V, galvanically isolated
1 start bit, 8 data bits, 1 stop bit, no parity
4800 / 9600 / ... / 115200 Baud
Connector X3 Pin No.
SUB-D Pin No.
17
2
16
3
18
5
Rear view with comparator outputs and outline drawings see pages 48 and 49.
ASM
www.asm-sensor.com
CAT-PR/PT-E-07
45