English
Language : 

9334 Datasheet, PDF (4/4 Pages) National Semiconductor (TI) – 8-Bit Addressable Latch
4
■ Supports multichannel measurement over a network
The 9334 LOGGER COMMUNICATOR is a program for use
on a PC and supports the connection of up to sixteen 8420-51,
8421-51, and 8422-51 MEMORY HiLOGGERs via LAN.
This allows the simultaneous data collection and display of up to
512 analog channels, 256 logic channels, and 64 pulse channels.
Measurement data can be downloaded to the disk drive of your
PC in real time.
By connecting your PC, HUB, and LAN with their respective
cables, you can easily use the 8420-51 to 8422-51 as multipoint
loggers.
■ Wide variety of display screens
In addition to the Waveform Display screen, the 9334 allows
you to display other screens, such as the Numeric Display
Screen, Monitor screen, and Alarm screen. This allows you
to display multiple screens, which means that you can view
waveforms and numerical values simultaneously, or confirm the
status of alarms on the Alarm screen while viewing the current
values on the monitor. Furthermore, you can print waveforms
displayed on the Waveform screen if you have a printer
connected to your PC
■ I want to view data while measuring...
The Waveform Display screen can be divided in two so that you
can observe previous trends while viewing the current trend.
Previous trend cursor measurements and parameter calculations
are possible.
■ Converting data and opening it in spreadsheets
Widely used spreadsheet programs (such as Excel) can be
used to edit measurement data and create reports. The 9334
LOGGER COMMUNICATOR allows you to convert acquired
waveform data to CSV format.
9334 LOGGER COMMUNICATOR
(Windows 95/98, NT4.0/2000/XP English version)
■ Real-Time Data Collection on a PC (TCP/IP Communications)
Supports Up to 16 HiLOGGERs
Ethernet
PC running 9334 Program
Data measured by the
HiLOGGER can be transferred
to the PC in real time.
Advantages of Ethernet - TCP/IP Connection
●10Base-T cables may be up to 100m long.
●The 9334 LOGGER COMMUNICATOR program is
available for immediate use on the PC.
●Automatic retransmission capability provides better
error handling than RS-232C serial communications.
9334 LOGGER COMMUNICATOR specifications
Compatible
units
8420-51, 8421-51, and 8422-51 MEMORY HiLOGGER
Media
One CD-R
Operating Computers running under Windows 95/98/Me or Windows NT4.0/2000/XP.
environment CPU: Pentium (133 MHz) or later, 64-MB memory or more
■ Interface: Ethernet ■ Number of units supported: 16
■ Number of measurement systems: eight
Data transfer ■ Internal memory: Internal memory data can be loaded from the 8420-51s
functions
■ Real-time transfer: data can be loaded in real time (maximum file size:
up to 200 MB), real-time load settings can be made using the remote
control
Display
functions
■ Waveform Display: displays acquired waveform data as images
■ Real-time Display: displays real-time transfers as images and allows the
time axis to be split
■ Digital Value Display: displays waveform data as digital values, and
allows images and digital values to be displayed simultaneously
■ Cursor function: allows you to display the time and potential differences
between cursors A and B, the time and electrical potential between each
cursor, and the absolute and relative times
■ Scroll function: available
■ Maximum number of channels: 256 analog channels, 256 logic
channels, and 64 pulse channels
■ Data load format: real-time and memory
■ Alarm Output Display: possible
Storage
function
■ Memory content: criteria settings and measurement data
(binary and text formats)
Data
conversion
functions
■ Target data: all data or data between cursors A and B
■ Data interval: simple interval, average value, absolute and maximum
values, maximum and minimum values (can be selected when saving)
■ Data conversion: can convert analog and pulse waveform data into
numerical values and logic data into binary
■ Data conversion format: CSV
■ Conversion channel: can be selected when saving
Print
functions
■ Target data: all data or data between cursors A and B
■ Print format: waveforms and numerical values
Parameter
calculation
functions
■ Target data: all data or data between cursors A and B
■ Calculation items: average value, peak value, maximum value, maximum
value time, minimum value, minimum value time, ON time, OFF time,
number of times ON, number of times OFF, standard deviation, area
Other
■ Marking function: inserts an event marker at the start of measurement
■ Search functions: Select from event marker, date (absolute and relative
time), trigger, maximum, minimum, peak, valley, alarm, level, window, or
volume of change
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
Shanghai Representative Office :
1704 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P.R.China
TEL +86-21-6391-0090, 0092
FAX +86-21-6391-0360
E-mail: info@hioki.cn
All information correct as of Jan. 27, 2006. All specifications are subject to change without notice.