English
Language : 

DS-0096 Datasheet, PDF (5/5 Pages) All Sensors Corporation – Millivolt Output Pressure Sensors
Specification Notes
note 1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
positive pressure applied to Port B.
note 2: Shift is relative to 25°C.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algerbraic difference between full scale output voltage and the offset voltage.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds.
Equivalent Circuit
+Vsupply
-Vout
+Vout
Input Resistance
5.0 k ohm
Output Resistance
3.0 k ohm
-Vsupply
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.
All Sensors
DS-0096 Rev B