English
Language : 

DS-0096 Datasheet, PDF (4/5 Pages) All Sensors Corporation – Millivolt Output Pressure Sensors
Performance Characteristics for 30 PSI-A-PRIME-MV
Parameter, note 1
Output Span, note 4
Offset Voltage @ zero absolute pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 3
Span Temperature Shift (0°C-70°C), note 2
Minimum
89.1
-
-
-
-
Nominal
90.0
-
-
0.15
-
Maximum
90.9
±0.5
±250
0.30
±1.0
Units
mV
mV
uV
%FSS
%FSS
Performance Characteristics for 100 PSI-D-PRIME-MV
Parameter, note 1
Output Span, note 4
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 3
Span Temperature Shift (0°C-70°C), note 2
Minimum
99.0
-
-
-
-
Nominal
100
-
-
0.15
-
Maximum
101
±0.3
±250
0.30
±1.0
Units
mV
mV
uV
%FSS
%FSS
Performance Characteristics for 100 PSI-A-PRIME-MV
Parameter, note 1
Output Span, note 4
Offset Voltage @ zero absolute pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 3
Span Temperature Shift (0°C-70°C), note 2
Minimum
99.0
-
-
-
-
Nominal
100
-
-
0.15
-
Maximum
101
±0.5
±250
0.30
±1.0
Units
mV
mV
uV
%FSS
%FSS
Performance Characteristics for 150 PSI-D-PRIME-MV
Parameter, note 1
Output Span, note 4
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 3
Span Temperature Shift (0°C-70°C), note 2
Minimum
89.1
-
-
-
-
Nominal
90.0
-
-
0.15
-
Maximum
90.1
±0.3
±250
0.30
±1.0
Units
mV
mV
uV
%FSS
%FSS
millivolt output prime grade pressure sensors