English
Language : 

LPT62-M Datasheet, PDF (2/3 Pages) Artesyn Technologies – Total Power: 60 - 80 Watts
LPT60-M Series Data Sheet
Environmental Specifications
Operating temperature
0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C startup
Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity
Operating; non-condensing 5% to 95%
Vibration
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to
500 Hz, operational
Storage temperature
-40 °C to 85 °C
Temperature coefficient
±.04% per °C
MTBF demonstrated
>550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Model Number
Output
Voltage
LPT62-M
+5 V
+12 V
-12 V
LPT63-M
+5 V
+15 V
-15 V
Minimum
Load
0.7 A
0.3 A
0A
0.7 A
0.3 A
0A
Maximum Load with Maximum Load with
Convection Cooling 30CFM Forced Air
7A
3A
0.7 A
7A
2.8 A
0.7 A
8A
3.5 A
1A
8A
3.3 A
1A
Peak Load1
10 A
6A
1.5 A
10 A
4A
1.5 A
Regulation2
±2%
±5%
±5%
±2%
±5%
±5%
Ripple
P/P (PARD)3
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as
a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System
Integrators, including through Distribution Channels. It is not intended for sale to End Users.
80W
60W
Output
Power
(Watts) 40W
20W
Power Derating Curve
30 CFM Forced Air Cooling
Natural
Convection
Cooling
40W
30W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C