LPT62-M Datasheet, PDF (1/3 Pages) Artesyn Technologies – Total Power: 60 - 80 Watts | |||
|
POWER
Data Sheet
Total Power: 60 - 80 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Triple
SPECIAL FEATURES
ÂÂ Medical safety approvals
ÂÂ Universal input
ÂÂ 3â x 5â footprint
ÂÂ Remote sense on main output
ÂÂ Built-in EMI filter
ÂÂ Low output ripple
ÂÂ Adjustable 5V output
ÂÂ Overvoltage protection
ÂÂ Overload protection
ÂÂ 110 KHz switching frequency
ÂÂ LPX60 enclosure kit available
ÂÂ RoHS compliant
SAFETY
ÂÂ VDE
ÂÂ UL
ÂÂ CSA
ÂÂ CE
0750/EN60601-1 (IEC601)
21310-3336-0015
UL2601
E182560
CSA 22.2 No. 601.1
LR109492
Mark (LVD)
LPT60-M Series
60 Watts
Electrical Specifications
Input
Input range
85 - 264 Vac
120 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
<18 A peak @ 115 Vac;
<36 A peak @ 230 Vac, cold start @ 25 °C
Input current
1.5A max. (RMS) @ 115VAC
Efficiency
70% typical at full load
EMI
FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class
A conducted; VDE 0878 PT3 Class A conducted
Safety ground
leakage current
<75 μA max. @ 50/60 Hz, 264 Vac input
Output
Maximum power
60 W for convection; 80 W with 30CFW forced air
Cross regulation
±2% on output 1; ±5% on outputs 2, 3
Adjustment range
-5, +10% minimum
Hold-up time
20 ms @ 60 W load, 115 Vac nominal line
Overload protection
Short circuit protection on all outputs. Case overload protected @ 110%
to 145% above peak rating
Overvoltage protection 5.7 to 6.7 Vdc on the main output
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
|
▷ |