English
Language : 

EXQ125-48S1V2J Datasheet, PDF (2/3 Pages) Artesyn Technologies – 36-100 W High Efficiency DC/DC Converters
EXQ125 Series
Single output
DC/DC CONVERTERS 36-100 W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
36 W
45 W
54 W
75 W
82.5 W
100 W
100 W
INPUT
VOLTAGE
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
OVP
1.45 Vdc
1.8 Vdc
2.3 Vdc
3 Vdc
3.9 Vdc
6 Vdc
14.4 Vdc
OUTPUT
VOLTAGE
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5V
12 V
OUTPUT
CURRENT
(MIN.)
0A
0A
0A
0A
0A
0A
0A
OUTPUT
CURRENT
(MAX.)
30 A
30 A
30 A
30 A
25 A
20 A
8.3 A
EFFICIENCY
(TYP.)
86.5%
87.5%
88.0%
90.0%
91.0%
92.0%
93.0%
REGULATION
LINE LOAD
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
MODEL
NUMBER (8,9)
EXQ125-48S1V2J
EXQ125-48S1V5J
EXQ125-48S1V8J
EXQ125-48S2V5J
EXQ125-48S3V3J
EXQ125-48S05J
EXQ125-48S12J
Part Number System with Options
EXQ125-48S1V2-ZRNJ
EX = Open Frame, Through Hole
Q = 1/4 Brick
Output Wattage Class
125 = 125 Watts
Input Voltage
48 = 48 Volts (33 V to 75 V range)
Number of Outputs
S = Single
Output Voltage
1V2 = 1.2 V, 1V5 = 1.5 V etc
RoHS Compliance (8)
J = Pb-free (RoHS 6/6 compliant)
Pin Length of Standard Product
Blank = 0.200” (5.08 mm)
Pin Length of Modified Standard Product
N = 0.145” (3.68 mm)
K = 0.110” (2.79 mm)
(See Note 7)
Control Logic
Blank = Positive
R = Negative
Blank = Standard Product
Z = Zero Undershoot,
Soft Turn-off Characteristic
(Applies to 1.5 V, 1.8 V,
2.5 V and 3.3 V models only)
Notes
1 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max. Deviation varies by model, see
Longform Datasheet.
2 The EXQ125 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 118.
3 Recommended input fusing is a 5 A HRC 200 V rated fuse.
4 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5 Measured with no external Pi filter. Significant reduction possible with
external filter. See Application Note 118.
6 Start-up into resistive load.
7 Contact the factory for Modified Standard pin length products.
8 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
9 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
PROTECTION
Short circuit
Overvoltage
TELECOM SPECIFICATION
Central office interface A
Continuous
Non-latching clamp
ETS300-132-2, input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
File Name: exq125s.pdf Rev (02): 17 Nov 2005