English
Language : 

BXB100-24S12FLTJ Datasheet, PDF (2/3 Pages) Artesyn Technologies – Total Power: 66 - 100 W
BXB100 Series Data Sheet
General Specifications
Efficiency
(See Efficiency Table)
Insulation voltage
Input/Case
Input/Output
Output/Case
1500 Vdc
1500 Vdc
1500 Vdc
Switching frequency
Fixed
500 kHz typ.
Approvals and
VDE0805, EN60950, IEC950
standards (See Note 5) UL1950, CSA C22.2 No. 950
Case material
Aluminum baseplate with plastic case
Material flammability
UL94V-0
Weight
110 g (3.88 oz)
MTBF
Bellcore 332
MIL-HDBK-217F @
40 °C C, 100% loaded
1,400,000 hours
580,000 hours min.
EMC Characteristics
Conducted emissions
(See Note 3)
EN55022 (See Note 3)
FCC part 15
EN55022, CISPR22
Level A
Level A
Level A
Environmental Specifications
Thermal performance Operating case temperature
Non-operating temperature
Altitude
Operating
Non-operating
Vibration
5 - 500 Hz
-40 °C to +85 °C
-55 °C to +125 °C
10,000 feet max.
40,000 feet max.
2.4 G rms (approx.)
Protection
Short-circuit
Overvoltage
Undervoltage
Thermal
Continuous, automatic recovery
Non-latching
Non-latching
100 °C baseplate, automatic recovery
Telecom Specifications
Central office
interface A
ETS300-132-2
Ordering Information
Model
Number
BXB100-24S12FLTJ
BXB100-48S05FLTJ
BXB100-48S12FLTJ
Output Power
(Max.)
100 W
100 W
100 W
Input
Voltage
18 - 36 Vdc
36 - 75 Vdc
36 - 75 Vdc
OVP
14.5 Vdc
6.5 Vdc
14.5 Vdc
Output Voltage
12 V
5V
12 V
Output Current
(Min)
0A
0A
0A
Output Current
(Max)
8.33 A
20 A
8.33 A
Efficiency
(Typical)
85%
83%
86%
Regulation
Line
Load
±0.05%
±0.1%
±0.05%
±0.1%
±0.05%
±0.1%
Notes:
1. Measured with 10 μF tantalum capacitor and 1 μF ceramic capacitor across output.
2. di/dt = 0.1 A/1 μs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo max. and 0.75
Io max. to 0.5 Io max.
3. Units should be characterised within systems. External components required.
4. Input fusing is recommended based on surge current and maximum input current.
5. This product is only for inclusion by professional installers within other equipment and must not
be operated as a stand alone product.
6. Simulated source impedance of 12 μH. 12 μH inductor in series with +Vin.
7. Active high remote on/off option is available (standard product is active low), designate with the
suffix ‘FHT’ e.g. BXB100-48S05FHTJ. Consult factory for further details and options.
8. Start-up into resistive load.
9 . “J” suffix designation for RoHS 6/6.
External Output Trimming
Output can be externally trimmed by using the method shown.
8
TRIM
UP
7
RT1
OR
RT2
TRIM
DOWN
6