English
Language : 

BXA3 Datasheet, PDF (2/3 Pages) Artesyn Technologies – 3W Wide Input DC/DC Converters
BXA3 Series
Single and dual output
DC/DC CONVERTERS 3W Wide Input DC/DC Converters
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
9-18VDC
9-18VDC
18-36VDC
18-36VDC
18-36VDC
36-75VDC
36-75VDC
36-75VDC
36-75VDC
OUTPUT
VOLTAGE
3.3V
15.0V
3.3V
5.0V
±5.0V
3.3V
5.0V
12.0V
15.0V
OUTPUT
CURRENT (1)
600mA
200mA
600mA
500mA
±250mA
600mA
500mA
250mA
200mA
INPUT
CURRENT (2)
245mA
335mA
122mA
140mA
140mA
61mA
69mA
83mA
83mA
TYPICAL
EFFICIENCY
68%
75%
68%
76%
76%
68%
76%
76%
76%
REGULATION
LINE (3)
LOAD (4)
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
±2.5%
2
MODEL
NUMBER (5)
BXA3-12S3V3
BXA3-12S15
BXA3-24S3V3
BXA3-24S05
BXA3-24D05
BXA3-48S3V3
BXA3-48S05
BXA3-48S12
BXA3-48S15
Notes
1 Maximum.
2 Maximum figure at full load (nominal).
3 Low line to high line.
4 Full load to no load.
5 An optional internal filter is available. When the filter is added, the BXA3 will
meet VDE0871-A, VDE0878-A and EN55022-A. Add the suffix ‘-F’ to the
model number, e.g. BXA3-12S15-F.
6 Conducted noise filtering to EN55022 level B may be accomplished by
putting the following capacitors across the input pins.
12VDC
5µF ceramic X7R dielectric type
24VDC
3µF ceramic X7R dielectric type
48VDC
1µF ceramic X7R dielectric type
7 Reverse voltage protection can be implemented by putting a fast blow fuse
on the positive input rail. Rate the fuse for 250mA at 48VDC input, 500mA
at 24VDC input and 1000mA at 12VDC input.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 Licence No. 5856
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
www.artesyn.com
File Name: BXA3.PDF Rev: 02 Oct 2002