POWER
Data Sheet
Total Power: 125 - 250 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Medical and ITE safeties
ƒƒ Active power factor correction
ƒƒ 3” x 5” footprint
ƒƒ Less than 1U high
ƒƒ EN61000-3-2 compliant
ƒƒ Remote sense
ƒƒ Power fail
ƒƒ Adjustable main output
ƒƒ Built-in Class B EMI filter
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ Isolated 12 V Fan output
ƒƒ LPX200 enclosure kit available
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ cULus
ƒƒ CB
ƒƒ CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
LPS200-M Series
250 Watts
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C
Efficiency
86% typical at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Power factor
0.99 typical
Safety ground
leakage current
275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power
125 W for convection (100 W for LPS202-M); 250 W (200 W for
LPS202-M) with 30CFM forced air
Adjustment range
± 10% minimum on the main outputs
Fan output
12 V @ 0.5 A convection, @ 1 A forced air isolated, ± 10%
Hold-up time
16 ms @ 250 W load, 120 Vac input
Overload protection
Short circuit protection on all outputs. Case overload protected @
110 - 160% above rating
Overvoltage protection 15 - 50% above nominal output
Logical Control
Power failure
Open collector logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.