DS1050-3 Datasheet, PDF (1/4 Pages) Artesyn Technologies – Distributed Power Bulk Front-End | |||
|
POWER
Data Sheet
DS1050
Distributed Power Bulk Front-End
Total Output Power: 1050 Watts
+3.3 or 5.0 Vdc Standby Output
Wide Range Input Voltage:
90 - 264 Vac
SPECIAL FEATURES
ÂÂ Active power factor correction
ÂÂ EN61000-3-2 harmonic compliance
ÂÂ Inrush control
ÂÂ 1U X 2U form factor
ÂÂ 19.0 W/in3
ÂÂ +12 Vdc output
ÂÂ Available in +3.3 V and +5.0 V standby
output versions
ÂÂ No minimum load required
ÂÂ Hot plug operation
ÂÂ N + 1 redundant
ÂÂ Internal ORâing fets
ÂÂ Active current sharing (10 - 100% load)
ÂÂ Built-in cooling fan (40 mm x 28 mm)
ÂÂ I2C communication interface bus
ÂÂ PMBus compliant
ÂÂ EEPROM for FRU data
ÂÂ Amber/green bi-color LED status
ÂÂ Internal fan speed control
ÂÂ Fan fail tach output signal
ÂÂ Full digital control
ÂÂ Two-year warranty
SAFETY
ÂÂ UL/cUL 60950 (UL Recognized)
ÂÂ NEMKO+ CB report EN60950
ÂÂ EN60950
ÂÂ CE mark
ÂÂ China CCC
Electrical Specifications
Input
Input raÂnge
180 - 264 (1050 W)
90 - 264 (1050 W)
Frequency
47 - 63 Hz, single phase AC
Inrush current
40 Apk maximum inrush current
Efficiency
> 92% typical at high line 50% load (Climate Saver Gold)
Conducted EMI
FCC Subpart J EN55022 Class B
Radiated EMI
FCC Subpart J EN55022 Class B
Power factor
0.99 typical
Leakage current
1.40 mA @ 240 Vac
Hold up time
12 ms minimum
Output
Main DC voltage
+12 V @ 87 A
Standby
+3.3 Vsb @ 4 A (5 V @ 2.5 A available)*
Adjustment range
± 5% on +12V only using I2C
Regulation
+12 Vdc; +5%/-5%
+3.3 Vsb; +5%/-5%
Overcurrent
+12 Vdc; latches off if overcurrent lasts over 1 second, otherwise it is
auto recovery (See Table 1 next page) +3.3 Vsb, 6 A max (hiccup
mode)
Overvoltage
Undervoltage
+12 Vdc; 13.2 - 14.4 Vdc
+3.3 Vsb; 3.76 - 4.30 Vdc
+12 Vdc; 9 - 10.8 V (latch off)
Turn-on delay
2 second max, 5 - 50 mS, monotonic rise
Main output rise time
5 - 50 mS, monotonic rise
*20 W standby available with derated efficiency
|
▷ |