English
Language : 

ANC50 Datasheet, PDF (6/7 Pages) Arch Electronics Corp. – AC-DC Power Module
ANC50 SERIES
EFFICIENCY VERSUS LOAD
ANC50-18S
VIN VS Efficiency
Input Voltage (V)
90
115
180
230
Efficiency (%)
88.70 90.37 90.64 91.36
264
91.30
95.00%
92.50%
90.00%
87.50%
85.00%
82.50%
80.00%
77.50%
75.00%
72.50%
70.00%
90V
115V
180V
VIN
230V
264V
VER : A_1 update : 2012.01.20
AC-DC Power Module
50 Watts
Load (%)
115V (%)
230V (%)
Load (%)
115V (%)
230V (%)
LOAD VS Efficiency
10
20
30
40
50
82.30 88.04 88.58 88.80 88.96
78.44 85.01 88.00 88.80 89.27
60
70
80
90
100
89.06 89.83 89.60 89.78 89.43
89.40 89.60 90.20 91.06 91.07
100.00%
90.00%
80.00%
70.00%
60.00%
50.00%
40.00%
30.00%
20.00%
10.00%
0.00%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
ANC50-24S
VIN VS Efficiency
Input Voltage (V)
90
115
180
230
Efficiency (%)
87.04 88.38 89.29 89.61
264
89.41
95.00%
92.50%
90.00%
87.50%
85.00%
82.50%
80.00%
77.50%
75.00%
72.50%
70.00%
90V
115V
180V
VIN
230V
264V
Load (%)
115V (%)
230V (%)
Load (%)
115V (%)
230V (%)
LOAD VS Efficiency
10
20
30
40
50
81.76 85.92 86.90 87.81 88.04
73.46 82.42 84.96 85.95 87.13
60
70
80
90
100
88.41 88.52 88.74 88.41 88.38
87.69 88.52 89.13 89.46 89.61
100.00%
90.00%
80.00%
70.00%
60.00%
50.00%
40.00%
30.00%
20.00%
10.00%
0.00%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-6-