English
Language : 

ANC50 Datasheet, PDF (1/7 Pages) Arch Electronics Corp. – AC-DC Power Module
ANC50 SERIES
KEY FEATURES
„ Switching Power Module for PCB Mountable
„ Fully Encapsulated Plastic Case
„ Regulated Output and Low Ripple and Noise
„ Small Size as ANC 15Watt with 50Watt Higher Power
„ Screw Terminal For Optional
„ CE, UL Approval (Pending)
„ 3-Years Product Warranty
VER : A_1 update : 2012.01.20
AC-DC Power Module
50 Watts
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output )
ANC50-5S ANC50-9S ANC50-12S ANC50-15S ANC50-18S ANC50-24S ANC50-48S
Max Output Wattage (W)
40W
40W
50W
50W
50W
50W
50W
Voltage
90-264 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Input
Current (Full load)
Inrush Current (<2ms)
1100 mA max. (115 VAC) / 600 mA max. (230 VAC)
30 A max. (115 VAC) / 50 A max. (230 VAC)
Leakage Current
0.75 mA max.
External Fuse (recommend)
3.15 A slow blow type
Voltage (V.DC.)
5V
9V
12V
15V
18V
24V
48V
Voltage Accuracy
±2%
Current (mA) max
8000
4440
4167
3333
2780
2083
1040
Line Regulation (LL-HL) (typ.)
±1%
Load Regulation (5-100%) (typ.) ±1%
Output
Minimum Load
0%
Maximum Capacitive Load
80000 uF 30000uF 20000 uF 18000 uF 10000uF 6000 uF
470uF
Ripple & Noise
100mV
100mV
120mV
150mV
180mV
240mV
480mV
Efficiency (at 230 VAC)
86%
89%
90%
90%
90%
89%
89%
Hold-up Time
12 ms min.
Switching Frequency
40~75 kHz
Over Power Protection
Hiccup technique, auto-recovery
Protection
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Isolation
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Environment Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>200,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.91 x 2.13 x 0.87 Inches ( 74.0 x 54.0 x 22.0 mm ) Tolerance ±0.5 mm
Physical
Case Material
Weight
Plastic resin with Fiberglass (flammability to UL 94V-0)
158 g
Cooling Method
Free air convection
Safety
Agency Approvals
CE, UL/cUL (Pending)
EMC
EMI (Conducted & Radiated Emission) EN 55022 (Pending)
EMS (Noise Immunity)
EN 55024 (Pending)
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-