AQC100 SERIES
VER : B_9 update : 2016.09.01
AC-DC Power Module
100 Watts
KEY FEATURES
 Switching Power Module for PCB Mountable
 High Efficiency up to 93% Typical
 Active PFC Function, >0.95 (230Vac), >0.99 (115Vac)
 Universal Input: 90-264 VAC
 Low Leakage Current, <250uA
 Four M3 Mounting Holes Optional on Bottom Side
 Remote ON/OFF Control
 EN55022 Class B Meets
 Class I and Class II Construction
 Continuous Short Circuit Protection with Hiccup Mode and Auto Recover
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max Output Wattage (W)
Voltage
AQC100-12S
AQC100-15S
85 W
85W
90-264 VAC or 120-370 VDC
AQC100-24S
100W
AQC100-48S
100W
Frequency (Hz)
47-63 Hz
Input
Current (Full load)
Inrush Current (<2ms)
<2.0 A max. (115 VAC) / <1.0 A max. (230 VAC)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 0.5 mA max.
Power Factor
PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load
Voltage (V.DC.)
12V
15V
24V
48V
Voltage Accuracy
±2%
Current (A) max
7.08
5.66
4.2
2.1
Line Regulation (LL-HL) (typ.)
±1%
Output
Load Regulation (5-100%) (typ.)
Minimum Load
±1%
3%
Maximum Capacitive Load (at 230VAC) 50,000µF
40,000µF
6,000µF
560µF
Ripple & Noise max.
120mV
150mV
200mV
240mV
Efficiency (typ.)
90%
90%
92%
93%
Hold-up Time
10 ms (110 VAC) min.
Protection
Over Power Protection
Over Voltage Protection
Auto recovery, 105 ~ 180% rated output power
Zener diode clamp
Short Circuit Protection
Auto recovery, Hiccup mode
Input-Output (V.AC)
3000V
Isolation
Input-FG (V.AC)
1500V
Output-FG .(V.AC)
500V
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Environment
Temperature Coefficient
Humidity
±0.03%/°C ( 0~50°C )
95% RH
MTBF
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Physical
Dimension (L x W x H)
Case Material
Weight
4.3 x 2.3 x 1.18 Inches ( 109.0 x 58.5 x 30.0 mm ) Tolerance 0.1 mm
Plastic resin (flammability to UL 94V-0)
362 g
Cooling Method
Free convection
Safety
EMC
Agency Approvals
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
CE, UL60950-1, CB
EN61000-6-3、EN 55022 class B (Conductive plane to be connected to safety earth)
EN 55024、EN61000-4-2,3,4,5,6,8,11
Surge
2KV L-N, 4KV L N-FG