English
Language : 

XC2500E-10 Datasheet, PDF (3/22 Pages) Anaren Microwave – 10 dB Directional Coupler
Insertion Loss and Power Derating Curves
Model XC2500E-10
Rev B
-0.04
-0.06
Typical Insertion Loss Derating Curve for XC2500E-10
typical insertion loss(f=2700Mhz)
-0.08
-0.1
-0.12
-0.14
-0.16
-0.18
-50
0
50
100
150
200
250
300
Temperature of the Part ( °C)
Power Derating Curve for XC2500E-10
250
power handling (f=2700MHz)
225
200
175
150
125
100
75
50
25
0
0
25
50
75 100 125 150 175 200 225
Base Plate Temperature (°C)
Insertion Loss Derating:
Power Derating:
The insertion loss, at a given frequency, of a group of
couplers is measured at 25°C and then averaged. The
measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at -55°C and 95°C. Based on
copper as well as dielectric losses, the insertion loss is
computed from -55°C to 300°C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature),
maximum continuous operating temperature of the
coupler, and the thermal insertion loss. The thermal
insertion loss is defined in the Power Handling section of
the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the power
handling decreases to zero.
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392