X3C06A4-03S Datasheet, PDF (3/25 Pages) Anaren Microwave – Very Low Loss
`
Insertion Loss and Power Derating Curves
0
-0.05
Typical Insertion Loss Derating Curve for X3C06A4-03S
typical insertion loss (f=450Mhz)
typical insertion loss (f=860Mhz)
-0.1
-0.15
-0.2
-0.25
-0.3
-100 -50
0 50 100 150 200 250 300 350
Temperature of the Part (oC)
Model X3C06A4-03S
Rev A
X3C06A4-03S Power Derating Curve
450 MHz Band
860 MHz Band
900
800
700
600
500
400
300
200
100
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
Mounting Interface Temperature (oC)
Insertion Loss Derating:
Power Derating:
The insertion loss, at a given frequency, of a group of
couplers is measured at 25C and then averaged. The
measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at 85C and 150C. A best-fit line
for the measured data is computed and then plotted
from -55C to 150C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature),
maximum continuous operating temperature of the
coupler, and the thermal insertion loss. The thermal
insertion loss is defined in the Power Handling section of
the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the power
handling decreases to zero.
If mounting temperature is greater than 95C, Xinger
coupler will perform reliably as long as the input power
is derated to the curve above.