English
Language : 

X2AS_10 Datasheet, PDF (3/4 Pages) Anaren Microwave – SMT Crossover
Typical Performance: 0.5 GHz to 6.0 GHz
Model X2AS
Rev C
Return Loss X2AS
-10
Insertion Loss X2AS
0
-20
-0.1
-30
-0.2
-40
-55C
25C
-50
85C
100
150C
-60
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Freq (MHz)
-0.3
-55C
25C
-0.4
85C
100
150C
-0.5
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Freq (MHz)
Mounting
In order for Xinger crossovers to work optimally, there
must be 50Ω transmission lines leading to and from all of
the RF ports. Also, there must be a very good ground to
the corners of the crossover to insure proper electrical
performance. If either of these two conditions are not
satisfied, insertion loss, VSWR and isolation parameters
may not meet published specifications.
When a surface mount crossover is mounted to a printed
circuit board, the primary concerns are; insuring the RF
pads of the device are in contact with the circuit trace of
the PCB and insuring the ground plane of neither the
component nor the PCB is in contact with the RF signal.
Since the component is not symmetrical, the crossovers
are specifically oriented in the tape and reel. An example
of how the PCB footprint could look is shown below. In
specific designs, the 50Ω lines need to be adjusted to the
unique dielectric coefficients and thicknesses as well as
varying pick and place equipment tolerances.
Mounting Footprint
To ensure proper electrical and thermal performance
there must be a ground plane with 100%
solder connection underneath the part
Dimensions are in Inches [Millimeters]
X2AS Rev A Mounting Footprint
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392