English
Language : 

AM3906N Datasheet, PDF (2/5 Pages) Analog Power – Dual N-Channel Logical Level MOSFET
Analog Power
AM3906N
SPECIFICATIONS (TA = 25oC UNLESS OTHERWISE NOTED)
Parame te r
Symbol
Test Conditions
Limits
Min Typ Max Unit
Static
Drain-Source Breakdown Voltage
Gate-Threshold Voltage
V(BR)DSS
VGS(th)
VGS = 0 V, ID = -250 uA
VDS = VGS, ID = -250 uA
30
V
1.00 1.85 3.1
Gate-Body Leakage
IGSS
VDS = 0 V, VGS = 20 V
±100 nA
Zero Gate Voltage Drain Current
On-State Drain CurrentA
IDSS
ID(on)
VDS = 240 V, VGS = 0 V
VDS = 24 V, VGS = 0 V, TJ = 55oC
VDS = 5 V, VGS = 10 V
10
1
uA
10
A
Drain-Source On-ResistanceA
Forward TranconductanceA
rDS(on)
gfs
VGS = 10 V, ID = -2.5 A
VGS = 4.5 V, ID = 2.0 A
VDS = 5 V, ID = 2.5 A
0.082 0.099
Ω
0.113 0.142
3
S
Diode Forward Voltage
Dynamicb
VSD
IS = -1.6 A, VGS = 0 V
-0.7 -1.2 V
Total Gate Charge
Qg
2.3 3.3
Gate-Source Charge
Qgs
VDS = 15 V, VGS = 5 V, ID = 2.5 A
0.7 1.0 nC
Gate-Drain Charge
Qgd
0.9 1.4
Switching
Turn-On Delay Time
td(on)
6.5 13
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = 5 V,
ID = 2.5 A,
= 10 V, RG = 6 Ω
VGEN
11 19
ns
13 24
Fall-Time
tf
3
7
Notes
a. Pulse test: PW <= 300us duty cycle <= 2%.
b. Guaranteed by design, not subject to production testing.
Analog Power (APL) reserves the right to make changes without further notice to any products herein. APL makes no warranty,
representation or guarantee regarding the suitability of its products for any particular purpose, nor does APL assume any liability arising out of
the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential
or incidental damages. “Typical” parameters which may be provided in APL data sheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer
application by customer’s technical experts. APL does not convey any license under its patent rights nor the rights of others. APL products
are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the APL product could create a situation where personal
injury or death may occur. Should Buyer purchase or use APL products for any such unintended or unauthorized application, Buyer shall
indemnify and hold APL and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such
unintended or unauthorized use, even if such claim alleges that APL was negligent regarding the design or manufacture of the part. APL is an
Equal Opportunity/Affirmative Action Employer.
July, 2002 - Rev. A
PRELIMINARY
2
Publication Order Number:
DS-AM3906_A