English
Language : 

AM1541CE Datasheet, PDF (2/3 Pages) Analog Power – High performance trench technology
Analog Power
AM1541CE
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Static
Gate-Source Threshold Voltage VGS(th)
VDS = VGS, ID = 250 uA (N-ch)
VDS = VGS, ID = -250 uA (P-ch)
1
-1
Gate-Body Leakage
IGSS
VDS = 0 V, VGS = ±20 V
Zero Gate Voltage Drain Current
IDSS
VDS = 32 V, VGS = 0 V (N-ch)
VDS = -32 V, VGS = 0 V (P-ch)
On-State Drain Current
ID(on)
VDS = 5 V, VGS = 4.5 V (N-ch)
VDS = -5 V, VGS = -4.5 V (P-ch)
1.5
-1.5
V
V
±10
uA
1
uA
-1
A
A
Drain-Source On-Resistance
rDS(on)
VGS = 10 V, ID = 1.2 A (N-ch)
VGS = 4.5 V, ID = 0.96 A (N-ch)
VGS = -10 V, ID = -0.8 A (P-ch)
VGS = -4.5 V, ID = -0.64 A (P-ch)
140
mΩ
190
300
mΩ
390
Forward Transconductance
gfs
VDS = 10 V, ID = 1.2 A (N-ch)
VDS = -10 V, ID = -0.8 A (P-ch)
3
5
S
S
Diode Forward Voltage
VSD
IS = 0.2 A, VGS = 0 V
IS = -1.2 A, VGS = 0 V
(N-ch)
(P-ch)
0.65
-0.66
V
V
Dynamic
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
Turn-On Delay Time
Rise Time
Turn-Off Delay Time
Fall Time
Qg
Qgs
Qgd
N - Channel
VDS = 10 V, VGS = 4.5 V, ID = 1.2 A
5
0.3
0.7
nC
td(on)
N - Channel
8
tr
td(off)
VDD = 10 V, RL = 8.3 Ω,
ID = 1.2 A,
13
ns
25
tf
VGEN = 4.5 V, RGEN = 6 Ω
8
Input Capacitance
Ciss
N - Channel
73
Output Capacitance
Reverse Transfer Capacitance
Coss
Crss
VDS = 15 V, VGS = 0 V, f = 1 MHz
25
20
pF
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
Qg
P - Channel
4
Qgs
Qgd
VDS = -10 V, VGS = 4.5 V, ID = -0.8 A
0.5
0.9
nC
Turn-On Delay Time
Rise Time
Turn-Off Delay Time
Fall Time
td(on)
tr
td(off)
tf
P - Channel
VDD = -10 V, RL = 12.5 Ω,
ID = -0.8 A,
VGEN = -4.5 V, RGEN = 6 Ω
8
10
ns
28
13
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Ciss
Coss
Crss
P - Channel
VDS = -15 V, VGS = 0 V, f = 1 MHz
120
28
25
pF
Notes
a. Pulse test: PW <= 300us duty cycle <= 2%.
b. Guaranteed by design, not subject to production testing.
Analog Power (APL) reserves the right to make changes without further notice to any products herein. APL makes no warranty,
representation or guarantee regarding the suitability of its products for any particular purpose, nor does APL assume any liability arising out of
the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential
or incidental damages. “Typical” parameters which may be provided in APL data sheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer
application by customer’s technical experts. APL does not convey any license under its patent rights nor the rights of others. APL products
are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the APL product could create a situation where personal
injury or death may occur. Should Buyer purchase or use APL products for any such unintended or unauthorized application, Buyer shall
indemnify and hold APL and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such
unintended or unauthorized use, even if such claim alleges that APL was negligent regarding the design or manufacture of the part. APL is an
Equal Opportunity/Affirmative Action Employer.
PRELIMINARY
2
Publication Order Number: