English
Language : 

AAT2550 Datasheet, PDF (5/35 Pages) Advanced Analogic Technologies – Total Power Solution for Portable Applications
AAT2550
Total Power Solution for Portable Applications
Electrical Characteristics1
VADP = 5V; TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = 25°C.
Symbol Description
Battery Charger
VADP
VUVLO
Adapter Voltage Range
Under-Voltage Lockout
UVLO Hysteresis
IQ
ISLEEP
ILEAKAGE
ISHDN
VBAT_EOC2
ΔVCH/VCH
VMIN
VRCH
ICH
ΔICH/ICH
VADPSET
KIA
RDS(ON)
TC
TP
TV
VSTAT
ISTAT
VOVP
ITK/ICH
ITERM/ICH
ITS
Quiescent Current
Sleep Mode Current
Reverse Leakage Current
Shutdown Current
End of Charge Voltage Accuracy
Output Charge Voltage Tolerance
Preconditioning Voltage Threshold
Battery Recharge Voltage Threshold
Charge Current
Charge Current Regulation Tolerance
ADPSET Pin Voltage
Current Set Factor: ICH/IADPSET
Charger Pass Device
Constant Current Mode Time-Out
Preconditioning Time-Out
Constant Voltage Mode Time-Out
Output Low Voltage
STAT Sink Current
Over-Voltage Protection
Pre-Charge Current
Charge Termination Threshold Current
Current Source from TS Pin
TS1
TS Hot Temperature Fault
TS2
IDATA
VDATA(H)
VDATA(L)
SQPULSE
TPeriod
FDATA
TREG
TLOOP_IN
TLOOP_OUT
TSD
TS Cold Temperature Fault
DATA Pin Sink Current
Input High Threshold
Input Low Threshold
Status Request Pulse Width
System Clock Period
Data Output Frequency
Thermal Loop Regulation
Thermal Loop Entering Threshold
Thermal Loop Exiting Threshold
Over-Temperature Shutdown Threshold
Conditions
Min
4.0
Rising Edge
ICHARGE = 100mA
VBAT = 4.25V
VBAT = 4V, ADP Pin Open
VEN = GND
4.158
2.80
100
Constant Current Mode
VIN = 5.5V
CT = 100nF, VADP = 5.5V
CT = 100nF, VADP = 5.5V
CT = 100nF, VADP = 5.5V
ISINK = 4mA
0.20
70
Threshold
310
Hysteresis
Threshold
2.2
Hysteresis
DATA Pin is Active Low 3.0
1.6
200
Typ
3.0
150
0.75
0.3
1.0
4.2
0.5
3.0
VBAT_EOC - 0.1
10
2.0
4000
0.25
3.0
25
3.0
8.0
4.4
10
7.5
80
330
15
2.3
10
50
20
90
110
85
145
Max Units
5.5
V
V
mV
3.0 mA
1.0 µA
µA
1.0 µA
4.242 V
%
3.15 V
V
1000 mA
%
V
0.35 Ω
Hour
Minute
Hour
0.4
V
mA
V
%
%
90 µA
350 mV
2.4
V
mV
mA
V
0.4
V
ns
µs
kHz
°C
°C
°C
°C
1. The AAT2550 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured
by design, characterization, and correlation with statistical process controls.
2. End of Charge Voltage Accuracy is specified over the 0° to 70°C ambient temperature range.
2550.2006.07.1.0
5