English
Language : 

AAT2514_08 Datasheet, PDF (4/14 Pages) Advanced Analogic Technologies – Dual Channel 600mA Step-Down Converter
SwitchRegTM
PRODUCT DATASHEET
AAT2514
Dual Channel 600mA Step-Down Converter
Electrical Characteristics
VIN = VEN = 3.6V, TA = 25°C, unless otherwise noted.
Symbol Description
Step-Down Converter
VIN
Input Voltage Range
IQ
Input DC Supply Current
VFB
Regulated Feedback
Voltage
IFB
ΔVOUT/
VOUT/ΔVIN
ΔVOUT/
VOUT/ΔIOUT
ILIM
TS
TSD
THYS
FOSC
RDS(ON)
VEN(L)
VEN(H)
IEN
FB Input Bias Current
Output Voltage Line
Regulation
Output Voltage Load
Regulation
Maximum Output Current
Startup Time
Over-Temperature
Shutdown Threshold
Over-Temperature
Shutdown Hysteresis
Oscillator Frequency
P-Channel MOSFET
N-Channel MOSFET
Peak Inductor Current
Enable Threshold Low
Enable Threshold High
EN Input Current
Power-On Reset
Threshold (POR)
Conditions
Active Mode, VFB = 0.5V
Shutdown Mode, EN1 = EN2 = 0V, VIN = 4.2V
TA = 25°C, Channel 1 or 2
TA = 0°C ≤ TA ≤ +85°C, Channel 1 or 2
TA = -40°C ≤ TA ≤ +85°C, Channel 1 or 2 (See Note 2)
VIN = 2.5V to 5.5V, IOUT = 10mA
IOUT = 10mA to 600mA
VIN = 3.0V
From Enable to Output Regulation
VFB = 0.6V
ILX = 300mA
ILX = 300mA
VIN = 3V, VFB = 0.5V; Duty Cycle <35%
VFB Ramping Up
VFB Ramping Down
Power-On Reset Delay
Power-On Reset On-Resistance
Min
2.5
0.5880
0.5865
0.5850
-30
600
1.2
1.5
-1.0
Typ
500
0.3
0.6000
0.6000
0.6000
0.11
0.0015
100
140
15
1.5
0.35
0.28
1.20
8.5
-8.5
175
100
Max
5.5
800
2.0
0.6120
0.6135
0.6150
30
0.40
1.8
0.45
0.45
0.3
1.0
Units
V
μA
V
nA
%/V
%/mA
mA
μs
°C
°C
MHz
Ω
A
V
V
μA
%
ms
Ω
1. Specifications over the temperature range are guaranteed by design and characterization.
2. The regulated feedback voltage is tested in an internal test mode that connects VFB to the output of the error amplifier.
4
www.analogictech.com
2514.2008.02.1.1