English
Language : 

AAT1232 Datasheet, PDF (13/17 Pages) Advanced Analogic Technologies – 24V 100mA Step-Up Converter
AAT1232
24V 100mA Step-Up Converter
(SELV=OUHT igh)
10.0
12.0
15.0
16.0
18.0
20.0
24.0
-
-
-
-
-
-
-
12.0
15.0
16.0
18.0
15.0
16.0
18.0
18.0
20.0
24.0
24.0
(SELVO=ULT ow)
-
-
-
-
-
-
-
10.0
12.0
15.0
16.0
18.0
20.0
24.0
10.0
10.0
10.0
10.0
12.0
12.0
12.0
15.0
15.0
15.0
18.0
R3 = 4.99kΩ
R1 (kΩ)
R2 (kΩ)
36.5
0
44.2
0
57.6
0
61.9
0
69.8
0
78.7
0
95.3
0
78.7
0
95.3
0
121
0
127
0
143
0
162
0
196
0
75.0
3.32
76.8
1.65
76.8
1.24
78.7
0.562
90.9
3.01
93.1
2.49
93.1
1.65
115
3.32
118
2.49
118
1.24
143
2.49
R3 = 20.0kΩ
R1 (kΩ)
R2 (kΩ)
147
0
182
0
232
0
249
0
280
0
316
0
383
0
316
0
383
0
487
0
511
0
590
0
649
0
787
0
301
13.0
309
6.65
309
4.99
316
2.21
374
12.1
374
10.0
374
6.65
464
13.3
475
10.0
475
4.99
576
10.0
Table 1: SEL Pin Voltage Control Resistor Values (1% resistor tolerance).
S2Cwire Serial Interface
AnalogicTech's S2Cwire serial interface is a propri-
etary high-speed single-wire interface available
only from AnalogicTech. The S2Cwire interface
records rising edges of the EN/SET input and
decodes into 16 different states. Each state corre-
sponds to a voltage setting on the FB2 pin.
S2Cwire Serial Interface Timing
The S2Cwire serial interface has flexible timing.
Data can be clocked-in at speeds up to 1MHz. After
data has been submitted, EN/SET is held high to
latch the data for a period TLAT. The output is sub-
sequently changed to the predetermined voltage.
When EN/SET is set low for a time greater than
TOFF, the AAT1232 is disabled. When disabled, the
register is reset to the default value, which sets the
FB2 pin to 0.6V if EN is subsequently pulled high.
EN/SET
Rising
Edges
1
2
3
4
5
6
7
8
FB2
Reference
Voltage (V)
0.60 (Default)
0.64
0.68
0.72
0.76
0.80
0.84
0.88
EN/SET
Rising
Edges
9
10
11
12
13
14
15
16
FB2
Reference
Voltage (V)
0.92
0.96
1.00
1.04
1.08
1.12
1.16
1.20
Table 2: S2Cwire Voltage Control Settings
(SEL = Low).
1232.2006.12.1.3
13