ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN MAX UNIT
Supply Voltage (VBATT, VCC, VCCA)
0
+5
V
Mode Control Voltage (VMODE)
0
+3.5
V
Enable Voltage (VEN_CELL, VEN_PCS)
0
+3.5
V
RF Input Power (PIN)
-
+10
dBm
Storage Temperature (TSTG)
-40 +150
°C
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure
to absolute ratings for extended periods of time may adversely affect
reliability.
AWT6321
Table 3: Operating Ranges
PARAMETER
MIN TYP MAX UNIT
COMMENTS
Operating Frequency (f)
824
1850
-
849
1915
MHz
Cellular
PCS
Supply Voltage (VCC and VBATT)
+3.2 +3.4 +4.2
V
Enable Voltage (VEN)
+2.2 +2.4 +3.1
0
-
+0.5
V
PA "on"
PA "shut down"
Mode Control Voltage (VMODE)
+2.2 +2.4 +3.1
0
-
+0.5
V
Low Bias Mode
High Bias Mode
Cellular RF Output Power (POUT)
CDMA
+27.5 (1) +28.0
-
dBm
PCS RF Output Power (POUT)
CDMA
+27.5 (1) +28.0
-
dBm
Case Temperature (TC)
-30
-
+85
°C
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Notes:
(1) For operation at VCC = +3.2 V, POUT is derated by 0.5 dB.
Data Sheet - Rev 2.2
3