English
Language : 

HPS-100 Datasheet, PDF (15/24 Pages) ams AG – Automotive Hydrogen Sensor
HPS-100 − Specifications
Description
Operating Pressure
EMC
Dimensions (L, Ø)
Stud
O-ring
Weight
Material
Filter membrane
IP code
Value
0.3 – 3 bar(a)
Automotive requirements
Mechanical
L=93.5mm Ø = 30mm
M14x1.5 acc. to standard ISO 6149-3
ID: 11.3 ± 0.2 mm, rec. cord size 2.2 ± 0.08 mm
alt. cord size 2.4 ± 0.08 mm
77 g
Stainless steel and PBT GF30
Pall SUPOR 450R, 0.45 μm
IP6K7 and IP6K9K
The figure below describes the specification of the different
variants of HPS-100
Figure 20:
Specification of the Different Variants of HPS-100
Description
CAN interface
CAN bit rate (kbits/s)
PWM output
Default
On Request
Version 2.0 ISO 11898
n.a.
500
250
n.a.
-
Yes
ams Datasheet
[v1-00] 2015-Apr-06
Page 15
Document Feedback