English
Language : 

10-552682-11G Datasheet, PDF (7/54 Pages) Amphenol Corporation – Amphenol Tri-Start Subminiature Cylindrical Connectors
Tri-Start
specifications
CONTACT RATING
Contact
Size
22D
20
16
12
10 (Power)
8 (Power)
4
0
Test Current (Amps)
Crimp
5
7.5
13
23
33
46
80
150
Hermetic
3
5
10
17
NA
NA
NA
NA
Maximum Maximum
Millivolt Drop MIllivolt Drop
Crimp*
Hermetic*
73
85
55
60
49
85
42
85
33
NA
26
NA
23
NA
21
NA
* When using silver plated wire.
Contact
Size
22D
Crimp Well Data
Nominal
Well Diameter Well Depth
.0345 ± .0010
.141
20
.047 ± .001
.209
16
.067 ± .001
.209
12
.100 ± .002
.209
10 (Power) .137 ± .002
.355
Hermetic Data
Min. Well
Well Diameter Depth
.036
+ .004
– .000
.094
.044
+ .004
– .000
.125
.078
+ .004
– .002
.141
.116
+ .004
– .002
.141
NA
NA
8
.181 ± .002
.490
NA
NA
4
.281 ± .002
.490
NA
NA
0
.453 ± .002
.585
NA
NA
Service
Rating
M
Suggested Oper. Voltage
(Sea Level)
AC (RMS)
DC
400
550
SERVICE RATING
Test Voltage
(Sea Level)
1300 VRMS
Test Voltage
50,000 Ft.
550 VRMS
Test Voltage
70,000 Ft.
350 VRMS
Test Voltage
110,000 Ft.
200 VRMS
N
300
450
1000 VRMS
400 VRMS
260 VRMS
200 VRMS
I
600
850
1800 VRMS
600 VRMS
400 VRMS
200 VRMS
II
900
1250
2300 VRMS
800 VRMS
500 VRMS
200 VRMS
Please note that the establishment of electrical safety factors is left entirely in the designer’s hands, since he is in the best position to know what peak voltage,
switching surges, transients,etc. can be expected in a particular circuit.
Finish
FINISH DATA
Non-Hermetic Shell Components
Military
Service Class
Proprietary
Anodic Coating (Non-Conductive)
Electroless Nickel
Olive Drab Cadmium Plate Nickel Base
Stainless Steel with Nickel Plate
Stainless Steel
** Add Suffix (005) to part number.
C
F (Metal)
M (Composite)
W (Metal)
J (Composite)
S
K
RX**
RF
RW
RS
RK
Material / Finish
Stainless Steel
Stainless Steel with Nickel Plate
Hermetic Shell Components
Military
Y
N
Service Class
Proprietary
Y
YN
5