English
Language : 

A43E26161 Datasheet, PDF (7/44 Pages) AMIC Technology – 1M X 16 BIT X 4 BANKS LOW POWER SYNCHRONOUS DRAM
AC Operating Test Conditions
(VDD = 1.7V~1.95V, TA = 0°C to +70°C or TA = -25ºC to +85ºC)
Parameter
AC input levels
Input timing measurement reference level
Input rise and all time (See note3)
Output timing measurement reference level
Output load condition
0.9 x VDDQ/0.2
0.5 x VDDQ
tr/tf = 1/1
0.5 x VDDQ
See Fig.2
Value
Output
10.6KΩ
1.8V
VOH(DC) = VDDQ-0.2V, IOH = -0.1mA
13.9KΩ VOL(DC) = 0.2V, IOL = 0.1mA
30pF
OUTPUT
ZO=50Ω
A43E26161
Unit
V
V
ns
V
VTT =0.5V x VDDQ
50Ω
30pF
(Fig. 1) DC Output Load Circuit
(Fig. 2) AC Output Load Circuit
AC Characteristics
(AC operating conditions unless otherwise noted)
Symbol
Parameter
tCC
CLK cycle time
tSAC
CLK to valid
Output delay
tOH
Output data hold time
tCH
CLK high pulse width
tCL
CLK low pulse width
tSS
Input setup time
tSH
Input hold time
tSLZ
CLK to output in Low-Z
tSHZ
CLK to output in Hi-Z
CL=CAS Latency.
CL=3
CL=2
CL=3
CL=2
CL=3
CL=2
CL=3
CL=2
CL=3
CL=2
CL=3
CL=2
-95
Min
Max
Unit
Note
9.5
1000
ns
1
15
-
7
ns
1,2
-
8
2.5
-
ns
2
3.5
-
ns
3
3.5
-
3.5
-
ns
3
3.5
-
3
-
ns
3
3
-
1.5
-
ns
3
1
-
ns
2
-
7
ns
-
8
*All AC parameters are measured from half to half.
Note : 1. Parameters depend on programmed CAS latency.
2. If clock rising time is longer than 1ns, (tr/2-0.5)ns should be added to the parameter.
3. Assumed input rise and fall time (tr & tf) = 1ns.
If tr & tf is longer than 1ns, transient time compensation should be considered,
i.e., [(tr + tf)/2-1]ns should be added to the parameter.
(December, 2004, Version 1.0)
6
AMIC Technology, Corp.