7.0 Electro-Optical Characteristics (25°C)
Table 4: Electro-Optical Characteristics at 25°C
Parameter
Symbol
Parameter
Units
Note
Number of photo detectors
1408
Elements
Pixel-to-pixel spacing
Line scanning rate(1)
Clock frequency(2)
Bright output voltage(3)
Bright output non-uniformity(4)
Adjacent pixel non-uniformity(5)
Dark non-uniformity(6)
Tint
Fclk
Video output
Up
Uadj
Ud
62
423
3.33
1.2 +/-0.05
<+/-30
<25
<75
µm
µsec
MHz
V
%
%
mV
@ 3.33MHz clock frequency
See Note 2 for 5.0MHz operation
Specified for tint = 423µsec
Dark output voltage
Modulation transfer function(7)
Vd
200<Vd<300
mV
MTF
>40
%
See Note 7 for MTF & DOF
Notes:
(1) Tint: line scanning rate or integration time. Tint is determined by the interval of two start pulses (SP). See Note 2 for the high scanning speed operation.
(2) Fclk: main clock frequency. The call out is at 3.3MHz but electrically the module reliably operates to 5.0MHz. This modification will require adjusting the LED light
level and gain adjust.
(3) Vpavg = ∑ Vp(n)/1804
(4) Up = [(Vpmax - Vp) / Vp] x 100% or [(Vp - Vpmin) / Vp] x 100%
(5) Upadj = MAX[ | (Vp(n) - Vp(n+l) | / Vp(n)] x 100%
Upadj is the non-uniformity percentage pixel to pixel.
(6) Ud = Vdmax – Vdmin
Vdmin is the minimum output on a black document.
Vdmax is the maximum output voltage of a black document.
(7) MTF = [(Vmax - Vmin) / (Vmax + Vmin)] x 100 [%]. Depth of focus (DOF) range is defined with the MTF. MTF is the measure at the glass surface.
Vmax: maximum output voltage at 100lp/inch (At 1/2 of the optical Nyquest frequency)
Vmin: minimum output voltage at 100lp/inch
(8) lp / inch: line pair per inch
8.0 Recommended Operating Conditions (25°C)
Table 5: Recommended Operating Conditions at 25°C
Item
Symbol
Min.
Mean
Max.
Power supply
Vdd
4.5
5.0
5.5
VLED
4.5
5.0
5.5
Idd
28
32
36
ILED
130
180
235
Input voltage at digital high
Vih
Vdd-1.0
Vdd-.5
Vdd
Input voltage at digital low
Vil
0
0.6
Clock frequency
Fclk
3.33
5.0
Clock pulse high duty cycle
25
Clock pulse high duration(1)
50
Integration time(2)
Tint
0.282
5.0
Operating temperature
Top
25
50
Notes:
(1) The clock high duration is at a 5.0MHz maximum clock rate.
(2) Tint (minimum) is the minimum line integration time available at a 5.0MHz clock rate. See Note 2 under Table 4.