English
Language : 

EP3C5E144I7 Datasheet, PDF (6/34 Pages) Altera Corporation – Cyclone III Device Datasheet
1–6
Chapter 1: Cyclone III Device Datasheet
Electrical Characteristics
Table 1–5. Cyclone III Devices Bus Hold Parameter (Part 2 of 2) (1)
VCCIO (V)
Parameter Condition
1.2
1.5
1.8
2.5
3.0
3.3
Unit
Min Max Min Max Min Max Min Max Min Max Min Max
Bus-hold
low,
overdrive
current
0 V < VIN < VCCIO — 125 — 175 — 200 — 300 — 500 — 500 A
Bus-hold
high,
overdrive
current
0 V < VIN < VCCIO — –125 — –175 — –200 — –300 — –500 — –500 A
Bus-hold trip
point
—
0.3 0.9 0.375 1.125 0.68 1.07 0.7 1.7 0.8 2 0.8 2 V
Note to Table 1–5:
(1) The bus-hold trip points are based on calculated input voltages from the JEDEC standard.
OCT Specifications
Table 1–6 lists the variation of OCT without calibration across process, temperature,
and voltage.
Table 1–6. Cyclone III Devices Series OCT without Calibration Specifications
Description
Series OCT without
calibration
VCCIO (V)
3.0
2.5
1.8
1.5
1.2
Resistance Tolerance
Commercial
Max
Industrial and Automotive Unit
Max
±30
±40
%
±30
±40
%
+40
±50
%
+50
±50
%
+50
±50
%
OCT calibration is automatically performed at device power-up for OCT enabled
I/Os.
Table 1–7 lists the OCT calibration accuracy at device power-up.
Table 1–7. Cyclone III Devices Series OCT with Calibration at Device Power-Up Specifications
Description
Series OCT with
calibration at device
power-up
Calibration Accuracy
VCCIO (V)
Commercial Max
Industrial and Automotive
Max
Unit
3.0
±10
±10
%
2.5
±10
±10
%
1.8
±10
±10
%
1.5
±10
±10
%
1.2
±10
±10
%
Cyclone III Device Handbook
Volume 2