English
Language : 

EY1603 Datasheet, PDF (4/10 Pages) Altera Corporation – 40V, Low Quiescent Current, 150mA Linear Regulator
Page 4
Electrical Specifications Recommended Operating Conditions, unless otherwise noted. VIN = 14V, IOUT = 1mA, CIN = 0.1µF, COUT = 10µF,
TA = TJ = -40°C to +125°C, unless otherwise noted. Typical specifications are at TA = +25°C. Boldface limits apply over the operating temperature
range, -40°C to +125°C. (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 7) TYP (Note 7) UNIT
PROTECTION FEATURES
Output Current Limit
Thermal Shutdown
Thermal Shutdown
Hysteresis
ILIMIT
TSHDN
THYST
VOUT = 0V
Junction Temperature Rising
175 410
mA
+165
°C
+20
°C
NOTES:
5. Dropout voltage is defined as (VIN - VOUT) when VOUT is 2% below the value of VOUT when VIN = VOUT + 3V.
6. Enable to Regulation is the time the output takes to reach 95% of its final value with VIN = 14V and EN is taken from VIL to VIH in
5ns. For the adjustable versions, the output voltage is set at 5V.
7. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by
characterization and are not production tested.
EY1603 40V, Low Quiescent Current, 150mA Linear Regulator
09619
March 14, 2014
February 2014 Altera Corporation
Rev A