English
Language : 

EP5358XUI Datasheet, PDF (3/16 Pages) Altera Corporation – 600mA PowerSoC Synchronous Buck Regulator with Integrated Inductor
EP5358LUI/EP5358HUI
Absolute Maximum Ratings
CAUTION: Absolute Maximum ratings are stress ratings only. Functional operation beyond the
recommended operating conditions is not implied. Stress beyond the absolute maximum ratings may
cause permanent damage to the device. Exposure to absolute maximum rated conditions for
extended periods may affect device reliability.
PARAMETER
Input Supply Voltage
Voltages on: ENABLE, VSENSE, VSO – VS2
Voltages on: VFB (EP5358LUI)
Maximum Operating Junction Temperature
Storage Temperature Range
Reflow Temp, 10 Sec, MSL3 JEDEC J-STD-020C
ESD Rating (based on Human Body Mode)
SYMBOL
VIN
TJ-ABS
TSTG
MIN
-0.3
-0.3
-0.3
-65
MAX
6.0
VIN+ 0.3
2.7
150
150
260
2000
UNITS
V
V
V
°C
°C
°C
V
Recommended Operating Conditions
PARAMETER
Input Voltage Range
Operating Ambient Temperature
Operating Junction Temperature
SYMBOL
VIN
TA
TJ
MIN
2.4
-40
-40
MAX
5.5
+85
+125
UNITS
V
°C
°C
Thermal Characteristics
PARAMETER
Thermal Resistance: Junction to Ambient –0 LFM (Note 1)
Thermal Overload Trip Point
Thermal Overload Trip Point Hysteresis
SYMBOL
θJA
TJ-TP
TYP
85
+155
25
UNITS
°C/W
°C
°C
Note 1: Based on a four layer copper board and proper thermal design per JEDEC EIJ/JESD51 standards
03541
October 11, 2013
www.altera.com/enpirion Page 3
Rev F