Switching Characteristics
Page 21
Table 21 lists the TX VOD settings for Cyclone V transceiver channels.
Table 21. Typical TX VOD Setting for Cyclone V Transceiver Channels = 100 Ω—Preliminary
Symbol
VOD Setting (1) VOD Value (mV) VOD Setting (1) VOD Value (mV)
0
0
32
640
1
20
33
660
2
40
34
680
3
60
35
700
4
80
36
720
5
100
37
740
6
120
38
760
7
140
39
780
8
160
40
800
9
180
41
820
10
200
42
840
11
220
43
860
12
240
44
880
13
260
45
900
14
280
46
920
VOD differential peak to peak
15
300
47
940
typical
16
320
48
960
17
340
49
980
18
360
50
1000
19
380
51
1020
20
400
52
1040
21
420
53
1060
22
440
54
1080
23
460
55
1100
24
480
56
1120
25
500
57
1140
26
520
58
1160
27
540
59
1180
28
560
60
1200
29
580
61
1220
30
600
62
1240
31
620
63
1260
Note to Table 21:
(1) Convert these values to their binary equivalent form if you are using the dynamic reconfiguration mode for PMA
analog controls.
June 2013 Altera Corporation