English
Language : 

EP3C16E144C8N Datasheet, PDF (13/34 Pages) Altera Corporation – 1. Cyclone III Device Datasheet
Chapter 1: Cyclone III Device Datasheet
Electrical Characteristics
1–13
Table 1–18. Cyclone III Devices Differential I/O Standard Specifications (1) (Part 2 of 2)
I/O
Standard
VCCIO (V)
Min Typ Max
VID (mV)
Min Max Min
VIcM (V) (2)
Condition
VOD (mV) (3)
Max Min Typ Max
VOS (V) (3)
Min Typ Max
LVDS
(Column
I/Os)
2.375 2.5 2.625 100
0.05 DMAX  500 Mbps 1.80
—
0.55
500 Mbps  DMAX
 700 Mbps
1.80 247
—
600 1.125 1.25 1.375
1.05 DMAX > 700 Mbps 1.55
BLVDS
(Row I/Os) 2.375 2.5 2.625 100 — —
—
— —— — — — —
(5)
BLVDS
(Column 2.375 2.5 2.625 100 — —
—
— —— — — — —
I/Os) (5)
mini-LVDS
(Row I/Os) 2.375 2.5 2.625 — — —
—
— 300 — 600 1.0 1.2 1.4
(6)
mini-LVDS
(Column 2.375 2.5 2.625 — — —
—
— 300 — 600 1.0 1.2 1.4
I/Os) (6)
RSDS®
(Row
2.375 2.5 2.625 — — —
—
— 100 200 600 0.5 1.2 1.5
I/Os) (6)
RSDS
(Column 2.375 2.5 2.625 — — —
—
— 100 200 600 0.5 1.2 1.5
I/Os) (6)
PPDS®
(Row I/Os) 2.375 2.5 2.625 — — —
—
— 100 200 600 0.5 1.2 1.4
(6)
PPDS
(Column 2.375 2.5 2.625 — — —
—
— 100 200 600 0.5 1.2 1.4
I/Os) (6)
Notes to Table 1–18:
(1) For an explanation of terms used in Table 1–18, refer to “Transmitter Output Waveform” in “Glossary” on page 1–27.
(2) VIN range: 0 V  VIN  1.85 V.
(3) RL range: 90  RL  110  .
(4) LVPECL input standard is only supported at clock input. Output standard is not supported.
(5) No fixed VIN, VOD, and VOS specifications for BLVDS. They are dependent on the system topology.
(6) Mini-LVDS, RSDS, and PPDS standards are only supported at the output pins for Cyclone III devices.
July 2012 Altera Corporation
Cyclone III Device Handbook
Volume 2