EP53A7LQI Datasheet, PDF (12/19 Pages) Altera Corporation – 1A PowerSoC Light Load Mode Buck Regulator with Integrated Inductor
VMAX
VNOM
VMIN
Load
Step
LLM
Ripple
PWM
Ripple
VOUT
IOUT
Figure 6: VOUT Behavior in LLM Operation
Device exits LLM,
tests load current
Figure 7: VOUT Droop during Periodic LLM Exit
Many multi-mode DCDC converters suffer from
a condition that occurs when the load current
increases only slowly so that there is no load
transient driving VOUT below the VMIN threshold
(shown in Figure 6). In this condition, the
device would never exit LLM operation. This
could adversely affect efficiency and cause
unwanted ripple. To prevent this from
occurring, the EP53A7xQI periodically exits
LLM mode into PWM mode and measures the
load current. If the load current is above the
LLM threshold current, the device will remain in
PWM mode. If the load current is below the
LLM threshold, the device will re-enter LLM
operation. There will be a small droop in VOUT
at the point where the device exits and re-
enters LLM, as shown in Figure 7.
The load current at which the device will enter
LLM mode is a function of input and output
voltage. Figure 8 shows the typical value at
EP53A7LQI/EP53A7HQI
LLM Threshold Current vs. VOUT
250
200
150
VIN=5V (top curve)
100
VIN=4.2V
VIN=3.7V
50
VIN=3.3V (bottom curve)
0
0.8
1.1
1.4
1.7
2.0
2.3
2.6
2.9
3.2
VOUT (V)
Figure 8: Typical load current for LLM engage and
disengage versus VOUT for selected input voltages
Table 1: Load current below which the device can be
certain to be in LLM operation. These values are
guaranteed by design
VOUT
3.3
3.30
3.00
2.90
2.60
56
2.50
69
2.20
101
2.10
105
1.80
111
1.50
111
1.45
111
1.20
105
1.15
103
1.10
101
1.05
99
0.80
87
VIN
3.7
4.3
5.0
105
147
62
122
156
89
126
158
106
136
162
111
138
162
120
141
160
122
141
158
124
138
150
120
130
138
119
128
136
111
117
122
108
114
119
106
111
116
104
108
113
89
92
94
which the device will enter LLM operation. The
actual load current at which the device will
enter LLM operation can vary by +/-30%. Table
1 shows the minimum load current below which
the device is guaranteed to be in LLM
operating mode.
To ensure normal LLM operation, LLM mode
should be enabled/disabled with specific
sequencing. For applications with explicit LLM
pin control, enable LLM after VIN ramp up
complete; disable LLM before VIN ramp down.
For applications with ENABLE control, tie LLM
to ENABLE; enable device after VIN ramp up
complete and disable device before VIN ramp
01543
12
October 11, 2013
www.altera.com/enpirion
Rev D