AKD5365 Datasheet, PDF (8/27 Pages) Asahi Kasei Microsystems – Evaluation board Rev.A for AK5365 | |||
|
◁ |
ASAHI KASEI
[AKD5365]
2. [Function2 Dialog] : Dialog to evaluate IPGA
This dialog corresponds to only addr=04H, 05H.
Address Box: Input register address in 2 figures of hexadecimal.
Start Data Box: Input start data in 2 figures of hexadecimal.
End Data Box: Input end data in 2 figures of hexadecimal.
Interval Box:
Data is written to AK5365 by this interval.
Step Box:
Data changes by this step.
Mode Select Box:
If you check this check box, data reaches end data, and returns to start data.
[Example] Start Data = 00, End Data = 09
Data flow: 00 01 02 03 04 05 06 07 08 09 09 08 07 06 05 04 03 02 01 00
If you do not check this check box, data reaches end data, but does not return to start data.
[Example] Start Data = 00, End Data = 09
Data flow: 00 01 02 03 04 05 06 07 08 09
If you want to write the input data to AK5365, click âOKâ button. If not, click âCancelâ button.
3. [Write Dialog] : Dialog to write data by mouse operation
There are dialogs corresponding to each register.
Click the âWriteâ button corresponding to each register to set up the dialog. If you check the check box, data becomes
âHâ or â1â. If not, âLâ or â0â.
If you want to write the input data to AK5365, click âOKâ button. If not, click âCancelâ button.
 Indication of data
Input data is indicated on the register map. Red letter means âHâ or â1â and blue one means âLâ or â0â. Blank means the
part that is not defined in the datasheet.
 Attention on the operation
If you set up Function1 or Function2 dialog, input data to all boxes. Attention dialog is indicated if you input data or
address that is not specified in the datasheet or you click âOKâ button before you input data. In that case set up the dialog
and input data once more again. If you click âCancelâ button during operation, the operation is cancelled and returns to the
initial window.
<KM068900>
-8-
2002/04
|
▷ |