English
Language : 

AKD4113-B Datasheet, PDF (8/21 Pages) Asahi Kasei Microsystems – 192kHz digital audio receiver
ASAHI KASEI
[AKD4113-B]
Control Software Manual
„ Set-up of evaluation board and control software
1. Set up the AKD4113-B according to previous term.
2. Connect IBM-AT compatible PC with AKD4113-B by 10-line type flat cable (packed with AKD4113-B). Take care
of the direction of 10pin header. (Please install the driver in the CD-ROM when this control software is used on
Windows 2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control software”.
In case of Windows95/98/ME, this installation is not needed. This control software does not operate on Windows
NT.)
3. Insert the CD-ROM labeled “AKD4113-B Evaluation Kit” into the CD-ROM drive.
4. Access the CD-ROM drive and double-click the icon of “akd4113-b0.exe” to set up the control program.
5. Then please evaluate according to the follows.
„ Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click “Write default” button.
3. Then set up the dialog and input data.
„ Explanation of each buttons
1. [Port Setup] :
Set up the printer port.
2. [Write default] : Initialize the register of AK4113.
3. [All Write] :
Write all registers that is currently displayed.
4. [Read All] :
All the registers of AK4113 are read.
5. [Function1] :
Dialog to write data by keyboard operation.
6. [F3] :
Dialog of sequential writing.
7. [SAVE] :
Save the current register setting.
8. [OPEN] :
Write the saved values to all register.
9. [Write] :
Dialog to write data by mouse operation.
10. [Read] :
The data corresponding to each register is read.
<KM076501>
-8-
2004/11