English
Language : 

AKD5353 Datasheet, PDF (5/17 Pages) Asahi Kasei Microsystems – EVALUATION BOARD REV.B FOR AK5353
ASAHI KASEI
MEASUREMENT RESULTS
[Measurement condition]
• Measurement unit : ROHDE & SCHWARZ, UPD04
• MCLK
: 256fs
• BICK
: 64fs
• fs
: 48kHz
• BW
: 20Hz∼20kHz (fs=48kHz), 40Hz∼40kHz (fs=96kHz)
• Bit
: 24bit
• Power Supply : VA=VD=5V or 3V
• Interface
: DIT (fs=48kHz), Serial Multiplex (fs=96kHz)
• Temperature : Room
Parameter
S/(N+D)
DR
S/N
Input signal
1kHz, -1dB
1kHz, -60dB
no signal
Measurement filter
20kLPF
20kLPF, A-weighted
20kLPF, A-weighted
5V, 48kHz
83.3dB
98.4dB
98.6dB
3V, 48kHz
90.4dB
95.3dB
95.3dB
Parameter
S/(N+D)
DR
S/N
Input signal
1kHz, -1dB
1kHz, -60dB
no signal
Measurement filter
40kLPF
40kLPF
40kLPF
5V, 96kHz
84.7dB
95.3dB
95.3dB
[Measurement condition]
• Measurement unit : Audio Precision, System two
• MCLK
: 256fs
• BICK
: 64fs
• fs
: 48kHz
• BW
: 20Hz∼20kHz
• Bit
: 24bit
• Power Supply : VA=VD=5V or 3V
• Interface
: DIT
• Temperature : Room
Parameter
S/(N+D)
DR
S/N
Input signal
1kHz, -1dB
1kHz, -60dB
no signal
Measurement filter
20kLPF
20kLPF, A-weighted
20kLPF, A-weighted
5V, 48kHz
83.3dB
97.5dB
97.8dB
3V, 48kHz
88.8dB
94.6dB
94.6dB
[AKD5353]
<KM060503>
-5-
’99/11