ASAHI KASEI
[AKD4586]
„ Digital Inputs
Toslink(TORX176: PORT2) or BNC connector(J10) is used for digital inputs. Using Toslink or BNC connector is
selected by (JP2).
„ Digital Outputs
TOTX176(PORT2) is used for ADC output, and BNC connector(J3) is used for through data output.
„ Operation sequence
1) Set up the power supply lines. (See “Other jumpers set-up”.)
Name Color Voltage Contents
Contents
+12V
Orange
12∼15V Regulator and Analog
interface
-12V
Blue -15∼-12V Analog interface
AGND Black
0V
Analog ground
AGND jack should be always shorted.
DGND Black
0V
Digital ground
If JP1 is shorted ,DGND is not needed.
Table 1. Set up of power supply lines
Each supply line should be distributed from the power supply unit
2) Set-up the evaluation modes, jumper pins and DIP switches. (See the followings.)
3) Power on.
The AK4586 should be reset once bringing SW1(PDN) “L” upon power-up.
„ Serial control
The AK4586 can be controlled via the printer port (parallel port) of
IBM-AT compatible PC. Connect PORT1(uP-I/F) with PC by 10-line
flat cable packed with the AKD4586.
Take care of the direction of connector. There is a mark at pin#1.
The pin layout of PORT1 is as Figure 2.
PORT1
10 uP-I/F
GND
9
CSN
GND
CCLK
GND
CDTI
GND
CDTO
GND
NC
2
1
Figure 2 PORT1 pin layout