MEASUREMENT RESULTS
[Measurement condition]
⢠Measurement unit: Audio Precision System Two Cascade
⢠MCLK
: 256fs
⢠BICK
: 64fs
⢠fs
: 44.1kHz, 96kHz
⢠BW
: 10Hzâ¼20kHz (fs=44.1kHz), 10Hzâ¼40kHz (fs=96kHz)
⢠Bit
: 24bit
⢠Power Supply
: VDD=5V
⢠Interface
: DIR (fs=44.1kHz, 96kHz)
⢠Temperature
: Room
Parameter
S/(N+D)
DR
S/N
Input signal
1kHz, 0dB
1kHz, -60dB
no signal
Measurement filter
20kLPF
22kLPF
22kLPF, A-weighted
22kLPF
22kLPF, A-weighted
fs=44.1kHz
94.0dB
97.2dB
100.0dB
97.2dB
100.0dB
Parameter
S/(N+D)
DR
S/N
Input signal
1kHz, 0dB
1kHz, -60dB
no signal
Measurement filter
40kLPF
40kLPF
22kLPF, A-weighted
40kLPF
22kLPF, A-weighted
fs=96kHz
92.3dB
94.5dB
97.2dB
94.5dB
97.2dB