7. [Function5 Dialog]
The register setting file(*.akr) saved by [SAVE] function on main window can be listed up to 10 files, assigned to
buttons and then executed. When [F5] button is clicked, the window as shown in Figure 4 opens.
Figure 4. [F5] window
7-1. [OPEN] buttons on left side and [WRITE] button
(1) Click [OPEN] button and select the register setting file (*.akr).
(2) Click [WRITE] button, then the register setting is executed.
7-2. [SAVE] and [OPEN] buttons on right side
[SAVE]: The name assign of register setting file displayed on [Function5] window can be saved to the file. The file
name is “*.ak5”.
[OPEN]: The name assign of register setting file (*.ak5) saved by [SAVE] is loaded.
7-3. Note
(1) All files used by [SAVE] and [OPEN] function on right side need to be in the same folder.
(2) When the register setting is changed by [SAVE] Button on the main window, the register setting file (*.akr) should be
loaded again in order to reflect the change.